What is generator sizing?

Generator sizing in one line: if you are asking what size generator do I need, list what must run at once, add its running watts, add the starting surge of the largest motor load, then add headroom. This generator size calculator does exactly that arithmetic openly.

Generator sizing is the process of matching a generator to the electrical loads you actually intend to run, rather than to the size of your house, the number of rooms, or a salesperson's rule of thumb. Two homes with identical floor plans can need very different generators: one with gas heat, a gas water heater and a few LED lights might ride out an outage comfortably on a small portable unit, while an otherwise identical home with a well pump, an electric water heater and central air conditioning can need a machine three or four times larger. The loads decide, and that is why every credible sizing method — including the Generac and Cummins guides listed in the Sources — starts with a load list, not with square footage.

A generator has two ratings that matter for sizing, and confusing them is the most common buying mistake. Its running (continuous) rating is the power it can deliver hour after hour. Its starting (surge or peak) rating is the higher power it can deliver for a few seconds while a motor starts. A generator that is big enough on running watts can still fail you if its surge rating cannot start your well pump or air conditioner, and a generator bought only for a rare surge may be wastefully large for everyday running. Good sizing checks both numbers, which is why this page always shows a running total and a peak figure side by side before it recommends anything.

The generator sizing formula

Generator sizing formula: Running total = sum of all running watts. Peak watts = running total − running watts of the largest starting load + its starting watts. Recommended watts = peak watts x (1 + headroom). This page implements exactly these formulas, with 25% headroom by default.

Second, find the peak. Motors and compressors draw far more power in the first moments of starting than they do once running — commonly two to three times as much, and sometimes more. This page follows the standard single-largest-motor method used in manufacturer sizing guides: take the appliance with the highest starting watts, subtract its running watts from the total (because those running watts are already counted), and add its starting watts instead. In symbols, Peak = Running total − Run(largest starting load) + Start(largest starting load). Only one surge is counted because motors rarely all start at the exact same instant; if your situation breaks that assumption, the guide says so plainly below and the headroom is your first protection.

Third, apply headroom and convert units. Recommended watts = Peak x (1 + headroom), rounded to the nearest whole watt on this page. Kilowatts are watts divided by 1,000, shown here to two decimal places. Volt-amps are watts divided by the power factor: VA = W / PF, rounded to the nearest whole VA, with a default power factor of 0.8 that you can change. Nothing in the chain is hidden — every intermediate figure appears in the result breakdown, so you can reproduce the recommendation with a pencil from the numbers on this page.

Worked example: fridge, well pump, lights and furnace fan

Take a home that wants to keep four things running in an outage: a refrigerator (150 W running, 1,200 W starting), a well pump (1,000 W running, 2,000 W starting), a set of lights (300 W running, 300 W starting — lights have no motor and no surge) and a furnace fan (800 W running, 1,400 W starting). These are exactly the default selections in the calculator above, so you can reproduce every figure that follows without changing anything.

Step one, the running total: 150 + 1,000 + 300 + 800 = 2,250 W. Step two, the peak: the largest starting load is the well pump at 2,000 starting watts, so Peak = 2,250 − 1,000 + 2,000 = 3,250 W. Equivalently, the well pump adds 1,000 W of additional surge above its own running watts, and 2,250 + 1,000 = 3,250 W. Step three, headroom: 3,250 x 1.25 = 4,062.5 W, which this page rounds to the nearest whole watt and displays as 4,063 W recommended. In the other units the page shows, that is 4.06 kW and, at a 0.8 power factor, 4,063 / 0.8 = 5,079 VA (5,078.75 before rounding).

Read the recommendation the way you would shop with it: look for a generator whose running rating is at least the running total with margin and whose surge rating comfortably covers the peak — in practice, a model in the 4.1 kW class or the next standard size above it, since generators come in discrete model sizes, not in 4,063 W units. If you add a microwave (1,000 W) to the same list, the running total rises to 3,250 W and the peak to 4,250 W, and the recommendation moves to 5,313 W — try it above and watch which figure changes and which does not. The well pump still sets the peak, because its starting watts are still the highest on the list.

StepCalculationResult
Running total150 + 1,000 + 300 + 8002,250 W
Peak starting watts2,250 − 1,000 + 2,000 (well pump starts)3,250 W
Recommended (25% headroom)3,250 x 1.25 = 4,062.5, rounded4,063 W / 4.06 kW
Recommended VA (0.8 PF)4,063 / 0.8 = 5,078.75, rounded5,079 VA

Appliance wattage table: running and starting watts

The table below is the exact preset dataset the calculator uses, and the section the honesty warning on this page refers to: these wattages are typical estimates, not measurements of your appliances. A large modern refrigerator, an old refrigerator and a compact refrigerator do not draw the same power; a half-horsepower well pump and a one-horsepower well pump are different loads wearing the same name. Manufacturers publish typical ranges precisely because model, size, age and condition move the figure, and the Cummins sizing guide's own wattage chart carries the same warning that actual wattages may vary.

Use the presets for planning, then replace them with your own figures wherever the stakes are real. The nameplate — the metal plate or sticker on the appliance itself, or its manual and specification sheet — governs, always. If the plate lists amps and volts instead of watts, multiply them for running watts, and do the same with any locked-rotor or starting amp figure for starting watts. The two custom rows exist for exactly this: type your plate figures in and the calculator treats your appliance exactly like a preset one, quantities included.

Notice the pattern in the additional-surge column. Resistive and electronic loads — lights, heaters, a water heater, a microwave, a TV — have little or no surge: what they draw at switch-on is roughly what they draw while running. Motor and compressor loads — the fridge, freezer, pumps, furnace fan, air conditioner and washing machine — carry the surges, and they are the loads that decide your peak figure and, usually, your generator size.

ApplianceRunning wattsStarting wattsAdditional surge
Refrigerator150 W1,200 W1,050 W
Freezer100 W800 W700 W
Well pump1,000 W2,000 W1,000 W
Sump pump800 W1,300 W500 W
Furnace fan800 W1,400 W600 W
Central AC (3 ton)3,500 W5,250 W1,750 W
Lights (LED set)300 W300 W0 W
TV100 W100 W0 W
Microwave1,000 W1,000 W0 W
Washing machine500 W750 W250 W
Space heater1,500 W1,500 W0 W
Electric water heater4,500 W4,500 W0 W
Custom applianceYour figureYour figureDifference

Why starting watts matter

An electric motor at rest is, electrically, a very different device from the same motor spinning. In the first fraction of a second after switch-on, before the motor builds up speed and back-voltage, current rushes in at several times the running level. Compressors add their own burden: a fridge or air-conditioner compressor may be starting against refrigerant pressure. The result is the starting or surge wattage on every appliance chart — brief, but absolutely real, and the generator either delivers it or the motor does not start.

Headroom, kilowatts and VA

Headroom is deliberate spare capacity between what your calculation says and what you buy. This calculator applies it to the peak figure — Recommended = Peak x (1 + headroom) — and defaults to 25%, inside the 20 to 25% final margin Cummins recommends adding for home generator sizing. Headroom is not padding for its own sake. It absorbs wattage estimates that turn out low, a load you forgot, an appliance replaced by a hungrier model, and the simple fact that a generator run continuously at 100% of its rating runs hot, loud and short-lived compared with one cruising at three-quarters load.

Portable, inverter and standby generators

The size this page calculates is a power requirement, not a product type — three broad generator families can meet it, with different trade-offs. Portable generators are the familiar wheeled, petrol or dual-fuel machines: lowest cost per watt, started and connected manually, and connected to house circuits only through a properly installed inlet and transfer switch or interlock, or used directly with extension cords to individual appliances. They are the natural fit for essential-loads sizing in the range of the worked example.

Inverter generators are a quieter, cleaner-power subset of portables: they vary engine speed with load, use less fuel at light load, and produce the stable output sensitive electronics prefer. They typically top out at smaller sizes than conventional portables, though parallel kits can combine two units. Home standby generators are permanently installed, plumbed to natural gas or propane, start automatically through an automatic transfer switch, and are sold in kilowatts — roughly 7 kW upward into whole-home territory. For a standby unit, this calculator's load method is the same first step a dealer takes, but the final size also depends on fuel derating, load management and your panel, which is why the dealer or electrician's load calculation governs.

Fuel, runtime and derating

Sizing does not end at watts. Runtime — how long the machine runs on its fuel supply — decides whether a correctly sized generator is actually useful in a long outage. Portable fuel tanks are commonly rated for a stated number of hours at half load, and consumption rises steeply toward full load, which is another practical reason the headroom advice cuts both ways: a generator loafing at half load sips fuel and runs quietly for many hours, while one straining at its limit drinks its tank quickly and may need refuelling in the dark, in bad weather, while hot — which manufacturers warn against.

Common generator sizing mistakes

The first and most expensive mistake is sizing on running watts alone — adding up steady loads, buying that number, and discovering at the first well-pump start that surge was the real requirement. The second is the mirror image: adding every appliance's starting watts together, which assumes every motor in the house starts in the same second and produces an oversized, overpriced answer. The standard method sits between the two: all running watts, one largest surge.

Third is sizing to the whole house by default — listing everything you own instead of what an outage genuinely requires. Heaters, electric ovens, tumble dryers and EV chargers can double a requirement for loads most households happily live without for a day. Fourth is trusting typical wattages over nameplates when the nameplate is right there: the presets on this page are estimates, stated as such, and a single large motor whose plate figure differs from the preset can move the peak by more than the headroom covers. Fifth is comparing mismatched units — watts against VA, petrol ratings against propane use, surge headlines against running needs.

Sixth, and most often discovered too late, is forgetting how the power gets into the house: no transfer switch or inlet in the budget, extension cords through a cracked window as the permanent plan, or a generator sized for circuits the panel arrangement cannot actually feed. Size the load, the machine and the connection together — and bring the electrician in at the planning stage, not after the machine is in the driveway.

Transfer switches, carbon monoxide and safety

Two safety rules outrank every wattage figure on this page. The first is carbon monoxide: a running generator produces this odourless, lethal gas in quantity, and it must run outdoors, well away from windows, doors and vents — never in a house, garage, basement or porch, even with doors open. The American Red Cross generator safety guidance in the Sources exists because generator carbon monoxide poisoning is a recurring killer after storms, when people are tired, cold and improvising. Fit battery carbon monoxide alarms in the home and treat any headache or dizziness during generator use as an emergency.

The second rule is backfeeding. Connecting a generator to home wiring without a transfer switch or listed interlock can energise the utility lines outside your home — a lethal hazard for the line workers repairing the outage — and can destroy the generator when mains power returns. A licensed electrician should confirm whole-home installations and do all transfer-switch and panel work. Never plug a generator into a wall socket with a double-ended cord, under any circumstances, however temporary the plan feels.

Limits: what this calculator cannot do

Plainly stated: this calculator applies a standard sizing method to typical estimated wattages, and its result is a planning estimate, not a measurement, a guarantee or an installation design. It does not know your appliances' real nameplate figures unless you enter them, your panel capacity, your fuel supply, your altitude, or your local code. It assumes one largest motor starts while the rest run; simultaneous motor starts, locked-rotor figures far above the presets, or unusual loads like welders and large compressors can all push a real requirement above its answer.

It also does not size the parts of a system that are not watts: transfer switch amp rating, inlet and cable sizes, grounding, load-management modules, battery start capacity on standby units, or runtime on a given tank. Those are design questions for the generator manufacturer, the appliance manufacturers and — for anything touching your home wiring — a licensed electrician, whose judgement governs over any figure a web calculator produces.

Sources & References

Substitution disclosure: the U.S. Department of Energy's own appliance energy page (energy.gov/energysaver/estimating-appliance-and-home-electronic-energy-use) returned HTTP 404 when verified for this page, so the DOE method and typical wattages are cited here through the Virginia Cooperative Extension republication of that DOE material (source 4), which was verified live. Every source below was checked and returned HTTP 200 at the time this page was built. The sizing method on this page — running watts plus the single largest starting load, then a headroom margin — follows the Generac and Cummins guides listed first.