What is a BTU calculator?

A BTU calculator is an air conditioner sizing calculator: you enter the area of one room, and it tells you the cooling capacity, in British thermal units per hour (BTU/h), that a room air conditioner for that space should have, using the US Department of Energy and ENERGY STAR sizing table and its four published adjustments for sun, shade, occupants and kitchens. It answers the question shoppers actually type, in all its forms: btu calculator, ac btu calculator, how many btu do i need, and btu calculator for room size. The question sounds like it should have a single per-square-foot answer, and many pages give one, usually 20 BTU per square foot. The official table does not work that way, and the difference matters at the sizes people actually buy.

Look at what the table implies per square foot. At the top of the smallest band, 5,000 BTU for 150 sq ft is about 33 BTU per square foot. At 300 sq ft the table gives 7,000 BTU, about 23 per square foot. At 1,000 sq ft it gives 18,000 BTU, 18 per square foot, and at 2,500 sq ft it gives 34,000 BTU, under 14 per square foot. Small rooms need more capacity per square foot than large ones, because a small room has more wall, window and door surface relative to its floor area, and heat comes in through surfaces, not through floor space. A flat rule overstates large rooms and understates small ones. The table, built from how rooms actually gain heat, bends the other way, which is why this page uses the table itself rather than a shortcut dressed up as one.

One worked example runs through the whole guide, and the calculator opens with it pre-filled: a 300 sq ft bedroom, two regular occupants, normal sunlight, standard ceiling. Its answer is 7,000 BTU per hour, the table value for the 250 to 300 sq ft band, with no adjustment applying. The same room very sunny needs 7,700 BTU, and the same room used as a kitchen needs 11,000 BTU. A second anchor example, a 500 sq ft room, lands in the 450 to 550 band at 12,000 BTU, which is exactly 1 ton of cooling and 3.52 kW. If those four figures check out by hand against the table printed below, and the worked-example section shows every step, the method is sound for any room you enter after them.

How this AC BTU calculator works

Quick answer: Find your room area in the ENERGY STAR table to get the base BTU. Apply plus or minus 10 percent for a very sunny or heavily shaded room, add 600 BTU for each regular occupant beyond two, and add 4,000 BTU for a kitchen. Tons = BTU divided by 12,000. Kilowatts = BTU times 0.000293071.

The inputs fall into two groups. The room area comes first, in square feet or square metres, and it alone decides the base figure, because the table is a lookup, not a formula: the calculator finds the band your area falls in and takes that band capacity. Areas are read with the top of each band included, so 300 sq ft belongs to the 250 to 300 band at 7,000 BTU, matching the published example style where a band is written as one size up to the next. Below 100 sq ft the calculator returns the smallest table size, 5,000 BTU, and says so. Above 2,500 sq ft the table simply ends, and the calculator refuses to invent a number, because a space that large is no longer a one-room, one-unit problem.

The second group is the four adjustments, and their order is fixed and visible. The sunlight percentage is applied to the table value first, because ENERGY STAR words it as a percentage of capacity: a very sunny room increases capacity by 10 percent, a heavily shaded room reduces it by 10 percent. The two fixed additions follow: 600 BTU for each person beyond two who regularly uses the room, and 4,000 BTU if the unit will be used in a kitchen. The result is then shown three ways that are all the same capacity wearing different units: the adjusted BTU per hour, the nearest common retail size at or above it, and the conversions to tons and kilowatts. Nothing is rounded silently; the breakdown lists the base, the sunlight change, the occupant addition and the kitchen addition as separate lines, so a retailer recommendation can be checked against the same steps.

The worked examples, step by step

Start with the table lookup. A 300 sq ft room falls in the band written 250 to 300 sq ft, and the capacity printed for that band is 7,000 BTU per hour. With two occupants, normal sunlight and a bedroom rather than a kitchen, no adjustment applies, so the recommended capacity is the base itself: 7,000 BTU/h, which is 0.58 tons and 2.05 kW. That is the headline example, and it is deliberately plain: most bedrooms with two sleepers need exactly the table value and nothing added.

Now make the same room very sunny. The adjustment is plus 10 percent of the base: 7,000 times 1.10 = 7,700 BTU/h. No occupant or kitchen addition applies, so 7,700 is the final figure, and because shops stock common sizes, the nearest stocked unit at or above it is an 8,000 BTU model. Notice what the tool does not do: it does not round 7,700 down to 7,000 to make the answer look tidy. The adjusted figure is the recommendation; the retail line is only there to help you shop for it.

Make the same room a kitchen instead, with normal sunlight and two occupants. The sunlight factor is 1.00, the occupant addition is zero, and the kitchen addition is a flat 4,000 BTU: 7,000 + 4,000 = 11,000 BTU/h, with a 12,000 BTU unit as the nearest common size. The kitchen jump is the largest single adjustment in the system, larger than the sunlight change on any room under 40,000 BTU, which is why a kitchen of the same floor area as a bedroom genuinely needs a much bigger unit: cooking adds heat directly into the room the unit is trying to cool.

ExampleWorkingResult
300 sq ft bedroom, 2 people, normal sunTable band 250 to 3007,000 BTU/h
Same room, very sunny7,000 x 1.107,700 BTU/h
Same room, as a kitchen7,000 + 4,00011,000 BTU/h
500 sq ft room, standard conditionsTable band 450 to 55012,000 BTU/h = 1 ton = 3.52 kW

The 500 sq ft anchor shows the conversions cleanly. The table gives 12,000 BTU/h for the 450 to 550 band. Tons: 12,000 divided by 12,000 = 1 ton exactly, which is where the ton unit earns its keep as a quick mental scale. Kilowatts: 12,000 times 0.293071 watts = 3,516.85 watts, or 3.52 kW. Every figure in this guide was produced by the calculator on this page with these same steps, so you can reproduce each one exactly by entering the same numbers above.

The full ENERGY STAR sizing table

This is the complete room air conditioner sizing table published by ENERGY STAR, a joint program of the US Environmental Protection Agency and the US Department of Energy, reproduced in full because the calculator is only as trustworthy as the table behind it. The capacities are calculated for an 8-foot ceiling. If your room is smaller than 100 sq ft, use the first row. If it is larger than 2,500 sq ft, the table does not cover it, and neither does this calculator.

Area to be cooled (sq ft)Area (m2, approx.)Capacity needed (BTU/h)TonskW
100 to 1509.3 to 13.95,0000.421.47
150 to 25013.9 to 23.26,0000.501.76
250 to 30023.2 to 27.97,0000.582.05
300 to 35027.9 to 32.58,0000.672.34
350 to 40032.5 to 37.29,0000.752.64
400 to 45037.2 to 41.810,0000.832.93
450 to 55041.8 to 51.112,0001.003.52
550 to 70051.1 to 65.014,0001.174.10
700 to 1,00065.0 to 92.918,0001.505.28
1,000 to 1,20092.9 to 111.521,0001.756.15
1,200 to 1,400111.5 to 130.123,0001.926.74
1,400 to 1,500130.1 to 139.424,0002.007.03
1,500 to 2,000139.4 to 185.830,0002.508.79
2,000 to 2,500185.8 to 232.334,0002.839.96

Two features of the table deserve attention because they are where quick rules of thumb go wrong. First, the bands widen as rooms grow: the jump from the 250 to 300 band to the 300 to 350 band is 1,000 BTU, while the last band spans 500 sq ft for a 4,000 BTU step. Second, there is no 11,000, 13,000 or 16,000 row, because the table reflects the sizes room units are actually manufactured and sold in. When an adjustment lands between rows, as the sunny 7,700 BTU example does, the honest answer is the adjusted figure plus the nearest stocked size above it, which is exactly what the result panel shows.

Sun, shade, occupants and kitchens: the four adjustments

Quick answer: Very sunny room: add 10 percent. Heavily shaded room: subtract 10 percent. More than two regular occupants: add 600 BTU for each extra person. Kitchen: add 4,000 BTU. These are the only four adjustments ENERGY STAR publishes for this table.

Sunlight is the only percentage adjustment, and it cuts both ways. A very sunny room, typically one with large south or west facing windows that take direct sun through the hot part of the day, gains heat through the glass faster than the table average room, so capacity rises by 10 percent. A heavily shaded room, one shielded by trees, awnings or neighbouring buildings so it rarely takes direct sun, gains less, so capacity falls by 10 percent. Most rooms are neither, and the honest choice for most rooms is the middle setting. Choosing sunny for every room just to be safe is not caution; it is a systematic 10 percent oversize, and the oversizing section below explains what that costs in comfort.

People are heat sources. A resting adult gives off heat continuously, and the table already assumes two of them, which is why the adjustment only counts people beyond two, at 600 BTU each. A living room that regularly holds five people adds 1,800 BTU over the table value, which can move the recommendation up a full stocked size. A bedroom used by one person adds nothing and subtracts nothing: the adjustment has no negative side, because the table value is the floor for the room itself.

People also ask: how many BTU do I need per person?
Under the ENERGY STAR method, the first two regular occupants are already included in the table value. Each additional person who regularly uses the room adds 600 BTU per hour. Four regular occupants therefore add 1,200 BTU, and six add 2,400 BTU, on top of the sun or shade adjustment and any kitchen addition.

The kitchen addition is the bluntest instrument in the set: a flat 4,000 BTU, the same for a small galley kitchen as for a large kitchen diner. That flatness is a known coarseness of the method, not a mistake on this page. Cooking appliances dump their heat into the room air, and the table method prices that with one number rather than asking you to inventory your stove. If you cook heavily at the hottest time of day in a combined kitchen and living space, treat the result as a floor and favour the next stocked size up; if the kitchen is separate and the unit sits in the living room, the addition does not apply at all, because the unit is not cooling the kitchen.

BTU, tons and kilowatts: converting cooling capacity

Cooling capacity is sold in three units, and the same unit of equipment can appear in any of them depending on the seller and the country. The BTU per hour is the North American retail standard for room units. The ton is the trade standard for central systems and larger equipment, inherited from the era when cooling was measured against melting ice: one ton of cooling is the heat removal rate that melts one US ton of ice in 24 hours, fixed by definition at exactly 12,000 BTU per hour. The kilowatt is the metric standard, common on equipment sold outside North America and on specification sheets everywhere. The btu to tons calculator conversions are exact arithmetic, not estimates: tons = BTU per hour divided by 12,000, and kilowatts = BTU per hour times 0.000293071, because one BTU per hour equals 0.293071 watts by definition of the BTU and the watt.

BTU per hourTons of coolingKilowatts (kW)Typical use
5,0000.421.47Small bedroom window unit
8,0000.672.34Medium bedroom window unit
12,0001.003.52Large room unit, 1 ton
18,0001.505.28Very large room or small open plan
24,0002.007.032 ton central system size
36,0003.0010.553 ton central system size

One confusion to avoid: the kilowatt figure here is cooling capacity, the rate at which the unit removes heat, not the electricity the unit consumes. A 12,000 BTU unit delivers 3.52 kW of cooling while typically drawing roughly 1 kW of electrical power, because it moves heat rather than creating cold from electricity directly. The ratio between the two is the efficiency story told by the EER and CEER ratings on the label, which the DOE FEMP purchasing guidance in the sources covers. This calculator converts capacity only, and says so, because mixing capacity kilowatts with consumption kilowatts is how a correctly sized unit gets misread as an expensive one.

Why bigger is not better: oversizing and humidity

The most persistent myth in air conditioner buying is that a bigger unit is a safer buy. The US Department of Energy warns against it directly: an oversized room air conditioner cools the room to the thermostat setting quickly, then switches off, and in that short run it has not run long enough to remove the room humidity. The air ends up cool and clammy, which feels less comfortable than slightly warmer dry air, and the unit cycles on and off frequently, a pattern called short-cycling, which wastes energy at every start and wears the compressor faster. A smaller unit that runs longer, steadier cycles cools more evenly, dehumidifies properly and usually costs less to buy and to run. That is why this calculator shows the adjusted figure faithfully instead of quietly rounding up to the next size as a safety margin: the margin is the problem.

Humidity is not a side issue. The US Environmental Protection Agency advises keeping indoor relative humidity below 60 percent, and ideally between 30 and 50 percent, because sustained high humidity is the condition mould needs. A chronically oversized unit works directly against that target every day it runs, holding the temperature down while leaving the moisture up. Undersizing has its own honest cost, a unit that runs constantly on the hottest days and never quite reaches the setting, which is why the goal is neither bigger nor smaller but matched: the table value, the adjustments that genuinely apply, and the nearest stocked size at or just above the result. When an adjustment lands you exactly between two stocked sizes, the humidity argument is the tiebreaker for choosing the lower one in a humid climate, and the heat argument is the tiebreaker for choosing the higher one in a very hot, dry one.

What this calculator cannot do: ceilings, insulation, climate and Manual J

This tool applies the DOE and ENERGY STAR table exactly, and the table has stated boundaries that this page will not pretend away. The capacities are calculated for a standard 8 ft ceiling. A room with a 10 or 12 ft ceiling, a vaulted ceiling or an open mezzanine holds proportionally more air and usually needs more capacity, and the table offers no ceiling adjustment factor, so neither does this calculator. Poor insulation, single glazing, large west facing windows and a hot climate all push the true load above the table value, and good insulation, modern glazing and a mild climate pull it below. The table assumes a typical room in a typical US climate; it is a sizing guide for shopping, not a load calculation.

For whole-home systems the real standard is a Manual J load calculation, the method published by the Air Conditioning Contractors of America, which works room by room from construction details: wall and roof areas and insulation values, window sizes, types and orientations, infiltration, local design temperatures and internal gains. The DOE consumer guidance in the sources says the same thing in consumer language: a contractor should use Manual J to size home equipment, and rules of thumb based on floor area alone fail to account for climate and construction. Nothing on this page is a Manual J calculation, uses Manual J inputs, or should be presented to a contractor as one. Use this calculator to choose a window, portable or through-the-wall unit for one room, and to sanity-check a quote in tons or kilowatts. Use a professional with Manual J software to size a central system for a house.

The remaining limits are simple. The table ends at 2,500 sq ft, so the calculator stops there rather than extrapolating. It sizes cooling only, not heating. It does not model portable air conditioner derating, duct losses, or the difference between a window unit rating and real installed performance with a poor seal. And it cannot know your room: if your measurements or your sunlight choice are wrong, the output will be exactly, confidently wrong by the same amount, which is why every step of the working is printed for you to check.

Sources and References

Every figure in this guide was calculated with this page own table and adjustments, so you can reproduce each one exactly by entering the same numbers above. Disclosure: the ASHRAE public pages checked during research returned a 403 response to this page automated link check, so no ASHRAE page is linked; the load-calculation reference is carried instead by ACCA, the publisher of Manual J itself, and by the DOE guidance above, both verified live. All seven sources above returned a successful response when checked in November 2026.